Level

AstraZeneca

Analytical Development Scientist – Flow Cytometry

AI in this role

Major responsibilities

  • Develop, optimize, validate, and transfer flow cytometry analytical methods for cell therapy products, including CAR-T cell therapy and other advanced cell therapy modalities.
  • Develop and optimize multiparameter flow cytometry assays for cell identity, purity, viability, transduction efficiency, CAR expression, immune phenotyping, activation, differentiation, exhaustion, and other critical quality attributes (CQAs).
  • Design antibody panels and optimize staining conditions, compensation, controls, gating strategies, and assay parameters to ensure robust and reliable analytical performance.
  • Perform analytical method validation in accordance with applicable regulatory and quality requirements, including specificity, accuracy, precision, linearity, range, detection/quantitation capability, robustness, and stability, as applicable.
  • Perform troubleshooting and root-cause analysis for assay variability, unexpected results, and instrument-related issues; implement appropriate corrective and optimization measures.
  • Analyze and interpret flow cytometry data using FlowJo or equivalent software, and perform appropriate statistical analysis.
  • Prepare and maintain analytical development and validation protocols, reports, SOPs, analytical procedures, method transfer documents, and other technical documentation.
  • Support regulatory submissions, technology transfer, process development, QC method implementation, investigations, and audit preparation.
  • Operate, maintain, and troubleshoot flow cytometers and associated laboratory equipment in accordance with established procedures.
  • Collaborate with R&D, Process Development, QC, QA, and Regulatory teams to support project milestones and resolve analytical or product-related issues.
  • Contribute to analytical platform development, continuous improvement, technical training, and the implementation of new flow cytometry technologies.

Education, Qualifications, Skills and Experience

  • Master’s degree in Immunology, Cell Biology, Biotechnology, Bioengineering, Pharmaceutical Sciences, Medical Laboratory Science, or a related discipline.
  • Master’s degree or above is preferred.
  • Candidates with a strong background in flow cytometry and relevant industry or research experience are preferred.
  • Strong theoretical and practical knowledge of flow cytometry and multiparameter flow cytometry.
  • Proficient in flow cytometry panel design, antibody selection, compensation, controls, gating strategies, and data interpretation.
  • Proficient in FlowJo or equivalent flow cytometry data analysis software.
  • Good understanding of T-cell biology and relevant immunophenotyping markers.
  • Familiarity with cell therapy products and their critical quality attributes is highly desirable.
  • Knowledge of analytical method development, validation, and statistical analysis.
  • Familiarity with applicable regulatory and quality requirements, including Chinese Pharmacopoeia, ICH Q2, GMP, and data integrity requirements.
  • Experience with cell culture, ELISA, qPCR, cell-based assays, or other analytical techniques is an advantage.
  • Strong technical writing skills, with the ability to independently prepare protocols, reports, SOPs, and technical transfer documents.
  • Good English reading and writing skills, with the ability to understand scientific literature and prepare technical documentation.
  • Bachelor’s degree with 2+ years of relevant experience in flow cytometry, analytical development, cell therapy, biopharmaceutical R&D, or a related field.
  • Master’s degree or above with relevant research experience; outstanding fresh graduates may be considered.
  • Experience in cell therapy, biopharmaceutical companies, CRO/CDMOs, or GMP-regulated environments is preferred.
  • Experience in flow cytometry analytical method development, validation, or technology transfer is highly preferred.
  • Experience supporting IND submissions, regulatory inspections, analytical investigations, or method lifecycle management is a plus.

Date Posted

24-Aug-2026

Closing Date

30-Dec-2026

AstraZeneca embraces diversity and equality of opportunity.  We are committed to building an inclusive and diverse team representing all backgrounds, with as wide a range of perspectives as possible, and harnessing industry-leading skills.  We believe that the more inclusive we are, the better our work will be.  We welcome and consider applications to join our team from all qualified candidates, regardless of their characteristics.  We comply with all applicable laws and regulations on non-discrimination in employment (and recruitment), as well as work authorization and employment eligibility verification requirements.

How we score this

Analytical Development Scientist – Flow Cytometry at AstraZeneca scores 24 out of 100 on AI centrality, which makes it AI Level 1 of 4 (Little AI) on this board. The level measures how much of the work is AI, not seniority.

Classification

AI Level 1. The work itself involves no AI, or AI only appears as scenery, such as a company tagline.

  1. AI Level 480 to 100
  2. AI Level 360 to 79
  3. AI Level 240 to 59
  4. AI Level 10 to 39

Bands come from how often the tools, models and workflows of the role are named in the posting itself. Open the description and count.

Get new AI jobs by email

One email a week with the new AI jobs, each rated AI Level 1 to 4 for how much AI is in the work. No recruiter spam, unsubscribe in one click.

Free. One email a week. Unsubscribe in one click.

Similar roles

Other roles rated AI Level 1 at other companies.

What kind of AI work fits you?

Answer 12 practical questions in about three minutes. Get a simple profile, the work it points to, and live roles to explore next.

Find my next step

More jobs at AstraZeneca

Related searches

Same AI level